[email protected]

Chapter 9:Hanging, Bracing, and Restraint of System

If a shared support structure is used to support sprinkler pipe and other distribution systems per 9.1.1.3.1 and that structure does not provide seismic resistance as required in 9.3.5.1.4, the following shall be met:. The sprinkler pipe shall be braced using the method in 9.3.5.6 with the zone of influence including the water- filled sprinkler pipe and all other distribution systems that are Ferrous Pipe Fittings-Mechanical Joint - Ultimate Fire 8 Progress Drive Morrisville, PA 19067-3702 United States Tel:215-428-2400. View company website. company profile. contact. M. Accu-Fire was founded in May of

Ferrous sprinkler material and hospital MRI rooms - NFPA

Aug 24, 2009 · RE:Ferrous sprinkler material and hospital MRI rooms NewtonFP (Automotive) 20 Aug 09 12:09 Don't forget when using hanger rings to get the felt-lined rings if copper pipe is used. Fire Sprinkler Pipe:How to Perform an Obstruction In the first installment of our two-part series on obstruction investigations in fire sprinkler pipe, we reviewed when investigations should be conductedincluding 15 triggers highlighted by the 2020 edition of NFPA 25:Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. We also discussed the most Fire Sprinkler System Pipe Material:Steel Pipe Pros, Cons Jul 09, 2019 · Since the first fire protection systems were installed, the strength, durability, and extreme resistance to heat exhibited by black steel has made it the traditional leader of the fire sprinkler pipe market. With a melting point that falls between a whopping 2,600°F and 2,800°F (1,427°C and 1,538°C), steel pipe can withstand the heat of a

Home - Ultimate Fire Sprinkler Guide

Ferguson Fire & Fabrication. Ferguson Fire & Fabrication is the nations largest distributor of fire protection systems offering ISO-certified fabrication and a huge inventory of sprinkler heads, special hazards equipment, fittings, pipe and hangers. view profile visit website. How Seismic Protects Fire Sprinkler Systems from EarthquakesJan 23, 2020 · Pipe hanger rings support pipe. Riser clamps support risers. Because this hardware that is attached to structural members is vulnerable during an earthquake, section 18.5 of NFPA 13 requires seismic bracing for fire sprinkler risers, main lines, and branch lines 2.5 inches or larger if the building falls into a certain seismic design category. Pipe smaller than these areas is generally more Non-Ferrous Hanging Materials for MRI Room?Mar 17, 2020 · Thomas Jones III. 3/18/2020 08:45:34 am. So I have worked on three MRI rooms and have run into this everytime. There are no Nonmagnetic hanging materials. Even copper hangers, try putting a magnet up to them, it will stick. My last project I noticed all other trades were using magnetic materials to support their pipes and ducts.

PROPER HANGING OF FIRE SPRINKLER SYSTEMS

malleable cast iron, ring clips or approved adjustable hangers. Flat Utype hangers permitted if at least 3/16inch thick. Hangers required to be at least 12 inches from sprinklers to avoid interference, except round hangers were permitted as close as 3 inches. SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART Metra / Pace 8th Floor Renovation WET-PIPE SPRINKLER SYSTEMS Issued for Bid Chicago.IL 21 13 13 - 1 SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes:1. Pipes, fittings, and specialties. 2. Sprinklers. 1.2 SYSTEM DESCRIPTIONS Series DS-1 5 -factor Dry-type - Tyco Fire Productssprinkler fitting sprinkler face of fitting (127,0 to 1219,2 mm) increments in 1/4" (6,4 mm) order lengths:5" to 48" deflector to ceiling 1-3/4" (44,5 mm) minimum sprinkler fitting (refer to design criteria section) top of deflector criteria section) (refer to design sprinkler fitting sprinkler fitting face of in 1/4" (6,4 mm) increments (127

Viking Fire Sprinklers Viking Group Inc.

Stainless Steel Model N-2 1/2" Upright Sprinkler SIN VK130 Spray Pattern. Technical Data Sheet. Spray Pattern - Extended Coverage. 1/2" Extended Coverage Horizontal Sidewall 16' x 20' Sprinkler Spray Pattern. Technical Data Sheet. Microfast® Model M 1/2" Extended Coverage 16' x 18' Sidewall Sprinkler [DOC]211000 Fire Sprinkler and Standpipe Systems · Web viewUL listed for dry-pipe service. PIPE HANGERS. Hangers shall be listed in UL Fire Protection Directory or FM Approval Guide and of the type suitable for the application, construction, and pipe type. Alternative hangers shall be permitted per NFPA 13.Ferrous Hangers - Ultimate Fire Sprinkler GuideThe Ultimate Fire Sprinkler Guide is the database dedicated to fire sprinkler contractors, helping them find the products & services they needAccu-Fire Fabrication, Inc.,ASC Engineered Solution,Capital Fire Protection Co.,Ferguson Fire & Fabrication, Inc.,Reliable Automatic Sprinkler Co.,ACT Fabrication,ACT Pipe & Supply, Inc.,Action Fire Fab & Supply, Inc.,Allied Tube & Conduit/Atkore,Boradi Ltd,